The European powerful online platform with manufacturers and suppliers of pressure equipments​

pressure equipments plant

Guideline A-19

Question

Answer

For fluid power components and systems using liquids or gases of group 2 according to Article 13 paragraph 1 (b), the following applies :

1. Excluded from PED

1.1. due to exclusion of Article 1 paragraph 2 (f) (e.g. machinery directive)

  • piping and connecting devices for liquids of group 2 when DN ≤ 200 whatever the pressure is, and when DN > 200 and PS ≤ 500 bar
  • piping and connecting devices for gases of group 2 when DN ≤ 100 or PS x DN ≤ 3500 bar
  • pressure accessories (e.g. filter housing) no higher than category I
  • fluid power actuators, pumps and control valves no higher than category I.

1.2. due to exclusion of Article 1 paragraph 2 (j) (refer to guideline A-11)

  • fluid power actuators (e.g. motors, cylinders, …)
  • fluid power pumps
  • fluid power control valves (distributors).

2. Included in the PED

  • all accumulators (bladder, piston and diaphragm types)
  • pressure equipment not excluded by (1) above.