Guideline B-11
Article 14 paragraph 3 states that manufacturers can choose to apply one of the procedures which apply to a higher category if available. The words ‘if available’ make it clear that if an item of pressure equipment was classified as category IV, then a module from a higher category is not available. Even for those […]
Guideline B-18
No. Article 4 paragraph 3 explicitly prohibits CE marking of SEP pressure equipment. Article 13 paragraph deals with the classification of pressure equipment referred to in Article 4 paragraph 1 (not paragraph 3) and Article 14 sets out how the conformity assessment procedures should be determined for such equipment. Therefore Article 14 paragraph 3 does […]