Guideline A-23
No, only the aspects of pressure-related hazards are covered. (see also PED Guideline A-01)
Guideline A-35
These cartridges when transported separately are covered by ADR and consequently excluded from PED due to Article 1 paragraph 2(s). If such cartridge is used in a fire extinguisher (a PED assembly) it is in the scope of the PED directive . For further specific information see PED Guideline C-20. Note:see PED Guidelines A-01 and […]
Guideline B-14
Article 4 paragraph 1(a)(i) and Annex II, Table 2 are applied to vessels and therefore the requirements are relevant to the cylinder (bottle) of the portable extinguisher. The other parts of the portable extinguisher which are pressure equipment are classified according to Article 4 and assessed according to the appropriate Tables. Note:A portable extinguisher is […]